In this article, Steve Sandler presents three viable solutions for measuring ultra-low impedance with a maximum of 10 ms, each of which can be performed using sophisticated and novel FFT based 3-port measurement. These methods involve applying digitally modulated patterns to create modulated load currents up to 1500 A and recording the resulting power rail voltage perturbations.